INSTEK GPT-9803 CALIBRATION and INSTEK GPT-9803 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK GPT-9803 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   INSTEK GPT-9803   Description / Specification:   Spec Sheet 
INSTEK GPT-9803 5KV AC, 6KV DC Withstanding Voltage / IR Tester

The GW Instek GPT-9803 AC/DC Withstanding Voltage / Insulation Resistance Tester looks to meet a variety of safety standards such as IEC, EN, UL, CSA, GB, JIS and other safety-related requirements for the safety tests of electronic products and components. The GPT-9803 is a 3-in-1 model capable of performing AC withstanding, DC withstanding as well as insulation resistance tests.. It is equipped with a simple & clear panel layout, a high resolution dot matrix LCD display, and color LED indicators, allows operators to interpret measurement results easily and quickly. Specifications. AC Output-Voltage Range: 0.100kV to 5.000kV. AC Output-Voltage Resolution: 2V/step. AC Output-Voltage Accuracy: ± (1% of setting +5V) [no load]. AC Maximum Rated Load: 200 VA (5kV/40mA). Output-Voltage Waveform: Sine wave. Output-Voltage Frequency: 50 Hz / 60 Hz selectable. DC Output-Voltage Range: 0.100kV to 6.000kV. DC Output-Voltage Resolution: 2V/step. DC Output-Voltage Accuracy: ± (1% of setting +5V) [no load]. DC Maximum Rated Load: 50W (5kV/10mA). ARC Detect: Yes. RAMP (Ramp-Up Time): 0.1 to 999.9s. TIMER (Test Time): OFF, 0.5s to 999.9s. IR Output-Voltage: 50V to 1000V DC. IR Output-Voltage Resolution: 50V/step. IR Output-Voltage Accuracy: ± (1% of setting +5V) [no load]. IR Resistance Measurement Range: 1 Mohm to 9500 Mohm. RS232: Standard. USB (Device): Standard. GPIB: Optional.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK GPT-9803. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your INSTEK GPT-9803 CALIBRATION and/or INSTEK GPT-9803 5KV AC, 6KV DC Withstanding Voltage / IR Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: